Technical specifications
ISE accuracy 0.5 % f.s. / 1 % f.s.
Accuracy (pH) ±0,002
Accuracy (Salinity) ±1 % f.s.
O2 saturation accuracy ±10
Accuracy (Temperature) ±0,2 °C
Temperature calibration Yes
AQA calibration Yes
Temperature coefficent (max) 0,00 ... 10,00
DHS compatibility Yes
Pressure automatic compensation Yes
Salinity compensation Yes
Temperature compensation 0,0...100,0
Ultrapure water compensation Yes
PC Communication Micro USB
Automatic brightness control Yes
Cell constant 0,1 / 1 / 10
Criteria for stability of the measure Low - Med - High (pH)
Dimension
TDS factor 0.40 ... 1.00
Warranty
AQA Yes
Inputs 3 pairs BNC - RCA - Banana 4 mm Ref
Selectable languages Eng - Ita - Deu - Esp - Fra - Cze
Memory 10.000 data
Parameters pH, mV, ORP, ISE, Conducibilità, TDS, Salinità, Resistività, Ossigeno disciolto, Temperatura.
Password Yes, 4 numeric characters
Weight 0.45
Ion measuring range 0,001 ppm ... 199999 ppm
mV ORP measuring range -2000 ... +2000
PH calibration points 1...5 automatic values - 5 custom values
Dissolved Oxygen measuring range 0,00 ... 50,0
pH measuring range -2,00 ... +20,00
Barometric pressure measuring range 300 ... 1100
Resistivity measuring range 1,00 Ohm*cm ... 10,00 MOhm*cm
Salinity measuring range 0,01 ppt ... 100 ppt
O2 saturation measuring range 0,0 ... 400
Cond resolution 0,01 / 0,1 / 1 µS/cm (scala automatica)
ORP resolution 0,1 / 1
pH resolution 0,1 / 0,01 / 0,001
Barometric pressure resolution 1
O2 saturation resolution 0,1
Temperature resolution 0,1
Timer calibration due with alarm Si
Cell type 2 rings
ION measuring unit mg/l - g/l - mol/l
Power supply 4 x AA 1.5 V alkaline batteries
Accuracy (TDS) ±1 % f.s.
Accuracy (Resistivity) ±1 % f.s.
Barometric pressure accuracy ±0,5
pH alarm range Yes
Recognised pH buffers USA - NIST - DIN 19266
Swabs recognised Cond 84 µS - 147 µS - 1413 µS - 12,88 mS - 111,8 mS
Reference temperature +15 ... +30
DO Accuracy 1,5 f.s.
Accuracy (Cond) ± 1% f.s.
Display High-definition, backlit colour TFT
Electrode status indication Yes
Regulations CE
Calibration points Cond 1...4 automatic values / 1 custom value
ION calibration points 2...5
ORP calibration points 1
Cond measuring range 0,01 µS .... 1000 mS
TDS measuring range 0.1 mg/l ... 500 g/l
temperature measurement range -30 ... +130,0
Calibration Report Yes
DO resolution 0,01 mg/l