Item: 50110942
50110942 XS REVio Portable multiparameter meter - Cell 2301 T - Polarographic sensor - Without electrode
with conductivity cell 2301T and polarographic oxygen sensor, both with built-in temperature sensor and 3 m fixed cable, in hard case
Item: 50110942
50110942 XS REVio Portable multiparameter meter - Cell 2301 T - Polarographic sensor - Without electrode
Technical specifications | |
---|---|
ISE accuracy | 0.5 % f.s. / 1 % f.s. |
Accuracy (pH) | ±0,002 |
Accuracy (Salinity) | ±1 % f.s. |
O2 saturation accuracy | ±10 |
Accuracy (Temperature) | ±0,2 °C |
Temperature calibration | Yes |
AQA calibration | Yes |
Temperature coefficent (max) | 0,00 ... 10,00 |
DHS compatibility | Yes |
Pressure automatic compensation | Yes |
Salinity compensation | Yes |
Temperature compensation | 0,0...100,0 |
Ultrapure water compensation | Yes |
PC Communication | Micro USB |
Automatic brightness control | Yes |
Cell constant | 0,1 / 1 / 10 |
Criteria for stability of the measure | Low - Med - High (pH) |
Dimension | |
TDS factor | 0.40 ... 1.00 |
Warranty | |
AQA | Yes |
Inputs | 3 pairs BNC - RCA - Banana 4 mm Ref |
Selectable languages | Eng - Ita - Deu - Esp - Fra - Cze |
Memory | 10.000 data |
Parameters | pH, mV, ORP, ISE, Conducibilità, TDS, Salinità, Resistività, Ossigeno disciolto, Temperatura. |
Password | Yes, 4 numeric characters |
Weight | 0.45 |
Ion measuring range | 0,001 ppm ... 199999 ppm |
mV ORP measuring range | -2000 ... +2000 |
PH calibration points | 1...5 automatic values - 5 custom values |
Dissolved Oxygen measuring range | 0,00 ... 50,0 |
pH measuring range | -2,00 ... +20,00 |
Barometric pressure measuring range | 300 ... 1100 |
Resistivity measuring range | 1,00 Ohm*cm ... 10,00 MOhm*cm |
Salinity measuring range | 0,01 ppt ... 100 ppt |
O2 saturation measuring range | 0,0 ... 400 |
Cond resolution | 0,01 / 0,1 / 1 µS/cm (scala automatica) |
ORP resolution | 0,1 / 1 |
pH resolution | 0,1 / 0,01 / 0,001 |
Barometric pressure resolution | 1 |
O2 saturation resolution | 0,1 |
Temperature resolution | 0,1 |
Timer calibration due with alarm | Si |
Cell type | 2 rings |
ION measuring unit | mg/l - g/l - mol/l |
Power supply | 4 x AA 1.5 V alkaline batteries |
Accuracy (TDS) | ±1 % f.s. |
Accuracy (Resistivity) | ±1 % f.s. |
Barometric pressure accuracy | ±0,5 |
pH alarm range | Yes |
Recognised pH buffers | USA - NIST - DIN 19266 |
Swabs recognised Cond | 84 µS - 147 µS - 1413 µS - 12,88 mS - 111,8 mS |
Reference temperature | +15 ... +30 |
DO Accuracy | 1,5 f.s. |
Accuracy (Cond) | ± 1% f.s. |
Display | High-definition, backlit colour TFT |
Electrode status indication | Yes |
Regulations | CE |
Calibration points Cond | 1...4 automatic values / 1 custom value |
ION calibration points | 2...5 |
ORP calibration points | 1 |
Cond measuring range | 0,01 µS .... 1000 mS |
TDS measuring range | 0.1 mg/l ... 500 g/l |
temperature measurement range | -30 ... +130,0 |
Calibration Report | Yes |
DO resolution | 0,01 mg/l |